1
Bally Electromechanical / Re: 831-4Z payout counter coil not working
« Last post by wolftalk on Today at 10:26:14 PM »for small pays, the circuit probably goes thru an X3 relay switch - possibly wire 43-6 connecting to 94 when the X3 relay is unpowered.
electrically stepped payout on 831's is uncommon, but the only one I have info on the basic circuit is:
wire 90 -> payout relay switch wire 84 -> hopper pulse switches wire 43-6 -> X3 relay switch wire 94 -> payout counter step-up coil
for the high pays that need the X3 multiplication, it involves the X3 unit and is more complicated.
electrically stepped payout on 831's is uncommon, but the only one I have info on the basic circuit is:
wire 90 -> payout relay switch wire 84 -> hopper pulse switches wire 43-6 -> X3 relay switch wire 94 -> payout counter step-up coil
for the high pays that need the X3 multiplication, it involves the X3 unit and is more complicated.